Mert Medical Solutions

Full range. Less halo.

RayOne Galaxy, our next-generation spiral IOL platform, has been meticulously engineered using advanced artificial intelligence (AI) to redefine how your presbyopia patients experience the world. When patient satisfaction is non-negotiable, RayOne Galaxy emerges as a premium lens solution designed to minimise dysphotopic compromise while optimising visual performance.

Full range of vision

Smooth and continuous full range of vision1

Less halo

Minimised dysphotopsia1

Non-diffractive spiral optic

0% loss of transmitted light1

Available in toric powers

Clinically-proven and fully preloaded

The RayOne Galaxyand RayOne Galaxy Toric are part of the expansive RayOne family of fully preloaded IOLs – manufactured in the UK from a clinically proven lens material and on a lens platform recognised for its stability within the eye.

Vacuole free material for a glistening free IOL

97%

of patients achieved ≥ 6/12 distance CDVA at 6 months

94%

reported spectacle independence for distance and intermediate

0.98 µm

RMS wavefront aberration — near diffraction-limited performance

80+

countries where RayOne platform is trusted by surgeons

RayOne Galaxy
technical specification

Model NameRayOne GalaxyRayOne Galaxy Toric
Model NumberRAO605GRAO615X
Power RangeSphere +5.0 to +30.0 D (0.5 D increments)SE: +6.0 to +30.0 D (0.5 D increments) Cyl.: +0.75 D to +4.5 D (0.75 D increments)
MaterialSingle piece Rayacryl hydrophilic acrylic
Water content26% in equilibrium
UV protectionBenzophenone UV absorbing agent
UV light transmissionUV 10% cut-off is 380 nm
Refractive index1.46
ABBE56
Overall diameter12.5 mm
Optic diameter6.0 mm
Optic shapeBiconvex
AsphericityAberration-correcting technology
Optic edge designAmon-Apple 360° enhanced square edge (posterior)
Haptic angulation0°, uniplanar
Haptic styleClosed loop with Anti-Vaulting Haptic (AVH) technology
Delivery System
Injector typeSingle use, fully preloaded IOL injection system
Incision size1.65 mm nozzle for 2.2 mm incision
Bevel angle45°
Lens deliverySingle handed plunger
Estimated Constants for Optical Biometry
SRK/T
A-constant
Haigis
a0 / a1 / a2
HofferQ
pACD
Holladay I
SF
Holladay II
pACD
Barrett
LF / DF
Galaxy / Galaxy Toric118.61.0440.400.105.321.565.321.513.5
IOLcon.org Optimised Constants for Galaxy & Galaxy Toric118.42-0.3650.3790.1585.161.42N/A1.513.5

For Contact Ultrasound, the estimated A-constant is 118.0

Please note that the constants indicated for all Rayner lenses are estimates and are for guidance purposes only. Surgeons must always expect to personalise their own constants based on initial patient outcomes, with further personalisation as the number of eyes increases.

RayOne Galaxy
resources

Important Notice

Galaxy IOL is a medical device. Please read the Instructions for Use carefully before use. For professional use only. Rayner cannot offer medical advice to members of the public — for such advice consult a medical professional. Not all products are available in all markets. Contact your local Mert Medical Solutions representative for availability and regulatory status.